{"product_id":"three-pole-63amp-isolating-switch-kripal-ukf3-63","title":"Three Pole 63Amp Isolating Switch | Kripal UKF3-63","description":"\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 16.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003eThree Pole 63Amp Isolating Switch | Kripal UKF3-63\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003e\u003cbr\u003eThe \u003cb\u003eKripal UKF3-63 \u003c\/b\u003eis a 415V three-pole 63-amp isolating switch for air conditioners and industrial isolation. The \u003cb\u003eIsolating Switch\u003c\/b\u003e has an IP56 waterproof polycarbonate housing and meets IEC\/EN60947-3 and AS\/NZS60947-3 requirements.\u003cbr\u003e\u003cbr\u003eElectrical and air conditioning installers working on high-amperage machines typically struggle with safe isolation. Electrical work standards demand padlocked isolators for maintenance or emergency shutdown. Padlock-capable on and off positions and big terminals rated 6–8mm cable make the \u003cb\u003eKripal UKF3-63 \u003c\/b\u003esuited for heavy-duty applications on three-phase 415V circuits. The lid-base silica gel seal keeps moisture and dust out in outdoor settings.\u003cbr\u003e\u003cbr\u003eLicensed electricians and HVAC contractors like the \u003cb\u003eKripal UKF3-63\u003c\/b\u003e simple sizing: twin 25mm bolted entry on top and bottom mounting blocks allow easy installation on existing conduit runs, with 25–20mm reducers for smaller 20mm conduit. Internal neutral and earth links save termination hardware and ease fault-finding. \u003cb\u003eKripal UKF3-63 \u003c\/b\u003eisolates AC compressors, heat pump switchgear, and heavy machinery without voltage loss or performance lag without creative wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"font-size: 16.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003eFeatures\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003e\u003cbr\u003eThree-pole 63A 415V three-phase isolating switch for air conditioning compressors and industrial gear.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eIP66 weatherproofing protects contacts and internal components from water and dust in outdoor and exposed applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003ePolycarbonate enclosure—high-impact polycarbonate body provides insulation, strength, durability, and lightweight handling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eIn humid or salty environments, silica gel basket seal between lid and base protects.\u003cbr\u003ePadlockable on and off—padlocking in both positions meets electrical work safety and machinery isolation lockout requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eLarge termination blocks for 6–8mm cable allow thick cable lengths without crushing or voltage drop in high-amperage applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eTwin 25mm screwed entries, top and bottom—two mounting block entry points accept 25mm conduit, with reducers for smaller conduit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eIf the installation requires smaller conduit, two adapter rings are included to scale down conduit entry from 25mm to 20mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eFixed neutral and earth cables inside the enclosure ease three-phase installation and fault detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eCertified to international and AS\/NZS standards for industrial general-purpose isolating switches.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eThe 84 × 84 × 174mm body is compact and fits in confined areas without the need for big mounting blocks or conduit lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003eNot rated for load breaking, the \u003cb\u003eKripal UKF3-63\u003c\/b\u003e isolator should never switch live machines. Turn off the MCB or circuit breaker before using the isolator.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"font-size: 16.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003eWhere to use\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin; mso-fareast-language: EN-NZ;\"\u003e\u003cbr\u003e\u003cbr\u003eThe \u003cb\u003e63Amp Isolating Switch \u003c\/b\u003eprovides secure three-phase switchable isolation for split system and rooftop AC units, fulfilling installation and maintenance lockout requirements.\u003cbr\u003eSwitchgear for heat pumps and heating systems isolates high-amperage heating and heat recovery devices on three-phase power.\u003cbr\u003eThe \u003cb\u003e63Amp Isolating Switch\u003c\/b\u003e isolates industrial motor loads, pumps, fans, and spinning equipment for safe repair and maintenance.\u003cbr\u003eOutdoor electrical installations—IP66 protection makes the switch suitable for weatherproof cabinets, pole-mounted enclosures, and exposed outdoor switchboards.\u003cbr\u003eThree-phase inverter and battery isolation for medium-voltage DC or AC systems in remote or corrosive areas for renewable energy and solar installations.\u003cbr\u003eMain switch duties on temporary power distribution and standby generator cabinets are handled by the \u003cb\u003e63Amp Isolating Switch\u003c\/b\u003e.\u003cbr\u003e\u003cbr\u003eThe \u003cb\u003e63Amp Isolating Switch \u003c\/b\u003eshould not be used to switch loads frequently or make or break electrical current under normal load. Only as an isolating switch downstream of a main breaker or motor starter. Never use the \u003cb\u003eKripal UKF3-63\u003c\/b\u003e to switch off equipment under load—the contacts may arc and deteriorate. Use 63A only on three-phase 415V, not single-phase or 240V.\u003cbr style=\"mso-special-character: line-break;\"\u003e\u003c!-- [if !supportLineBreakNewLine]--\u003e\u003cbr style=\"mso-special-character: line-break;\"\u003e\u003c!--[endif]--\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Kripal","offers":[{"title":"Default Title","offer_id":47544938856610,"sku":"UKF3-63","price":34.24,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/3490\/1410\/files\/UKF3-1-1.png?v=1787151899","url":"https:\/\/coregrid360.co.nz\/products\/three-pole-63amp-isolating-switch-kripal-ukf3-63","provider":"CoreGrid 360","version":"1.0","type":"link"}